fbpx DHW CLT 200 | TIKI

DHW CLT 200

A+
  • Daily electricity consumption Qelec_ACC
    3,813 kWh
  • AEC annual electricity consumption
    806 kWh
  • Net/Gross/Weight with water
    133/145/327 kg
High quality insulation
Indirect tube air heaters
Automatic deforst
Overheating protection
Air ducts
Anti-legionella function

Extraordinary capacity: heats water up to 65°C without the use of an electric heater in the operating range from -7°C to +35°C.

A powerful and functional controller enables simple controlling and overview of the functioning of the pump.

Integrated coil heat exchanger for connecting external heat sources such as heating boilers, furnaces, or solar collectors.

Possibility of using in house generated solar PV power.

Independent ventilation function with user-defined fan operation time offers additional usability and comfort.

Technical properties

Characteristics

Declared load profile
L
Energy efficiency class
A+
Energy efficiency ƞwh
127 %
AEC annual electricity consumption
806 kWh
Daily electricity consumption Qelec_ACC
3,813 kWh
Thermostat temperature settings
55 °C
Sound power level LWA, indoors /Sound Pressure on 1m
59 / 48 dB(A)
Value of smart
0
Storage volume V
194,0 l
Mixed water at 40°C V40
248 l

Technical characteristics

Heating time A15/W10-55
05:13 h:min
Heating time A7/W10-55
06:06 h:min
Energy consuption by choosen cyclus A15/W10-55
3,86 kWh
Energy consumption by chosen cycle A7/W10-55
3,97 kWh
COPDHW(A15/W10-55) EN16147
3,12
COPDHW (A7 / W10-55) EN 16147
3,06
Standby power input according to EN16147
26 W
Refrigiant
R134a (GWP 1430)
Quantity of refrigiant
1,100 kg
Working range - air temperature
-7 / +35 °C
Working Air Flow
220-450 m3/h
Pressure Drop by 330 m3/h (60%/80%)
100 Pa

Electrical specifications

Nominal electrical power -compressor
490 W
Maximum power consumption
2490 W
Number of el.heaters x power
2 x 1000 W
Voltage/Frequecy
230/50 V/Hz
Electric protection
16 A
Degree of protection
IP 24

Storage tank

Enamelled steel / Protection Mg anode
+/+
Working pressure
0,6 (6) / 0,9 (9)/ 1(10) Mpa (bar)
Max working pressure heat exchanger
1,2 (12) Mpa (bar)
Surface area of the heat exchanger lower/upper
1,45 /- m2
Heat exchanger volume bottom /top
9,4/- l
Exchange power in continuous mode (max. coil output)
41,1 kW
Continous output ΔT=35K (4)
1010 l/h

Max temperature

Hot water tank heat pump
65 °C
Hot water tank electric heater
75 °C
Hot water tank heat exchanger
85 °C

Dimensions and connections

Average thickness of insulation
67 mm
Connections to the supply network
G1
Dimensions of air connections
Ø160 mm
Connections to the heat exchanger
G 1
Net/Gross/Weight with water
133/145/327 kg

Transportation data

Packaging dimensions [WxDxH]
800x800x1765 mm

Documents